د. سامحالغول

قسم الهندسة الميكانيكية والصناعية كلية الهندسة

الاسم الكامل

د. سامح خليفة عثمان الغول

المؤهل العلمي

دكتوراة

الدرجة العلمية

استاذ مساعد

ملخص

سامح الغول هو احد اعضاء هيئة التدريس بقسم الهندسة الميكانيكية والصناعية بكلية الهندسة. يعمل السيد سامح الغول بجامعة طرابلس كـاستاذ مساعد منذ 2014-12-25 وله العديد من المنشورات العلمية في مجال تخصصه

معلومات الاتصال

روابط التواصل

المؤهلات

دكتوراة

هندسة ميكانيكية
جامعة نوتنجهام - بريطانيا
11 ,2010

المنشورات

Optimizing thermal insulation of external building walls in different climate zones in Libya

An efficient way to reduce the energy required for conditioning buildings and therefore to reduce CO2 emission is the use of proper thermal insulation in buildings' external walls. This measure requires data from metrological stations that can be used in the optimization of the thermal insulation. The main objectives of this study are to construct thermal climatic zones for Libya and to specify the optimum insulation thickness for external walls for the different zones. This work is comprehensive as the metrological data from all existing 33 weather stations has been collected and used for identifying thermal zones. For the optimization of the construction of external walls, the most commonly used local wall structures are investigated: hollow concrete block, limestone block and hollow brick. In addition, four thermal insulation materials: extruded polystyrene, expanded polystyrene, rock wool and foamed polyurethane are used with every wall type. Optimum insulation thickness, energy savings, energy cost and payback periods were estimated for the 33 locations using life cycle cost analysis. A map is constructed for the thermal zones based on degree-day values for the entire country. The results show that limestone blocks with expanded polystyrene insulation form the optimum wall construction as it provides the minimum total cost for all locations. Depending on the Degree-day values, the optimum insulation thickness varies between 5.4 and 15.3 cm across the country with energy saving varies between 28 and 178 $/m2. Using the optimum thickness, the average CO2 emissions can potentially be reduced by about 85%. Finally, a contour map represents the optimum thickness of expanded polystyrene is presented in this work. arabic 12 English 80
Samah Khlifa Otman Alghoul, (1-2021)